• Low battery warning
• Warning message via SMS / eMail and status on web server
Excellent suitable for data recording during pumping tests. In addition to the continuous water level measurement in the well, the GPRS Datalogger type 255-G also has a tailor-made input channel to connect a Water Meter or Flow Meter to record the discharge continuously. If required, the device can also take over the additional recording of water quality parameters.
Designed for tough field use during pumping tests, you will quickly appreciate the benefits of the device. The robust and waterproof aluminum housing is easy to handle, the measuring probe(s) and the connection for the Flow Meter can be connected and disconnected by a watertight plug connection. The integrated battery casing made of stainless steel is waterproof and easily accessible for a battery change.
With the GPRS Datalogger type 255-G you have the possibility to monitor the pumping test from the office or at home. Online, you have access to up-to-date water level and flow data and instantly detect any irregularities. In addition, the device can be equipped with an alarm management, which alerts you when you reach limits directly on your smartphone.
General data | |
Dimensions | 200 x 100 x 70 mm |
Material: | Anodized aluminum, stainless steel |
Memory | non-volatile flash memory for approx. 190,000 data sets (depending on parameter); |
Measuring interval | Adjustable: 1 minute to 99 days / Optional: from 1 second |
Wall mounting | Easy to fix via bracket; |
Power supply | 3 pieces Alkaline batteries, Size: C; |
User interface | RS 232; can be addressed via serial and USB interface |
Connection Sensors | |
Input channels | - RS485 Modbus for HT probes - Input channel for connection of flow meter |
Connection type: | Via waterproof plug connection |
Data Transmission | |
Transmission frequency | Dualband 900 / 1800 MHz- Optional: Quadband with 850/1900 MHz |
Cellular network | Standard: 2G / Optional: 3G |
Transfer protocol | Standard: FTP, by setting also with SSL encryption |
Alarm Management | • 2 limit values can be defined for each parameter • Possibility to autom. switching of measuring and transmission interval • Low battery warning • Warning message via SMS / eMail and status on web server |
Environmental conditions | |
Operating temperature | -20°C to +65°C |
Protection class | IP 67 |